Publishing qPCR results: MIQE details and an RDML file from the original run
A reviewer asks for amplification efficiency, the threshold method and the raw data. The run was two years ago, on an instrument PC that has since been replaced.
The MIQE guidelines (Bustin et al., Clinical Chemistry, 2009) list what a qPCR paper should report so others can judge and repeat it. Several items come straight from the run file: the instrument, the cycling conditions, Cq values with the threshold and baseline used, NTC results and melt curves. RDML is the open data format developed alongside MIQE for sharing qPCR data. CycleView opens the original run file, lets you set and record threshold and baseline, exports RDML for supplementary data and exports SVG figures of curves and fold changes. Check your journal's own instructions for what they require.
What MIQE asks for, and where it lives
MIQE covers the whole experiment, from sample handling and RNA quality to primer design and normalisation. Some of that lives in your notebook. The data-analysis items live in the run:
- Instrument and run conditions: in the run method.
- Cq values and how they were determined: threshold, baseline, and which wells were excluded and why.
- Controls: NTC and other negative wells, and what they showed.
- Specificity: melt curves for intercalating-dye assays.
- Normalisation: the reference genes and the ΔΔCt or other method used.
With only a CSV of Cq values, most of these have to be reconstructed from memory.
From run file to manuscript
- Open each original run file in CycleView.
- Review curves, NTCs and melt peaks; set threshold and baseline deliberately and note the settings.
- Run ΔΔCt with your reference genes and calibrator, with replicate statistics.
- Export SVG figures for the paper: amplification curves, melt curves, fold-change charts.
- Export RDML for each run as supplementary data or for a repository.
Why RDML for supplementary data
RDML (Real-time PCR Data Markup Language) is an open XML-based format maintained by the RDML consortium. It stores the plate layout, targets, samples and the fluorescence data, so a reader can reanalyse the run in any tool that reads RDML, not just the one you used. A spreadsheet of Cq values cannot be reanalysed; an RDML file can.
When the instrument PC is gone
If you kept the original .eds, .ixo, .lc96p or .rex files, you can still answer a reviewer: open them on your own computer, check the curves and export RDML. That is a good reason to archive run files, not exports, at the end of every project.
Unpublished data stays local
Manuscript data is confidential until publication. CycleView processes every file on your computer and uploads nothing.
Get the run data ready for the paper
Open the original runs, export RDML and SVG figures. Processed locally, nothing uploaded.
Get CycleView
Thanks, we've received your email address.
Mac and Windows · runs locally · for research use, not for diagnosis.
FAQ
Does CycleView make my paper MIQE-compliant?
No tool can do that alone; MIQE covers sample preparation, assay design and more. CycleView helps with the items that come from the run data: Cq determination, controls, melt curves, normalisation and the raw data file.
Does my journal require RDML?
Requirements differ by journal. Check the author instructions. RDML is a widely used open format for sharing qPCR data whether or not it is required.
Can I convert Bio-Rad CFX runs to RDML?
CycleView does not open encrypted .pcrd files, but CFX Maestro can export RDML directly, and CycleView opens that.
Does it calculate amplification efficiency?
For per-reaction efficiency work, we recommend LinRegPCR, which is built for it. CycleView covers curves, Cq, ΔΔCt, figures and RDML export.